Features:
High precision, strong overload resistance and high reliability.
Application fields:
Various crane scales, lifting overload protection equipment, etc.
Capacity


Technical Specifications
| Rated Capacity | kg | 0-500 | Material | Aluminum Alloy | |
| Output Sensitivity | mV/V | 2.0±0.05 | Impedance | Ω | 350 |
| Zero Balance | %F. S. | ±1 | Insulation Resistance | MΩ/100V DC | ≥5000 |
| Non-Linearity | %F. S. | 0.02 | Operating Voltage | V | 5-15 |
| Hysteresis | %F. S. | 0.03 | Operating Temperature Range | °C | -20-80 |
| Repeatability | %F. S. | 0.02 | Safe Overload | %R. C. | 150 |
| Creep (30 min) | %F. S. | 0.03 | Ultimate Overload | %R. C. | 200 |
| Temp. Effect on Sensitivity | %F.S./10°C | 0.03 | Cable Specification | m | Φ5*3m |
| Temp. Effect on Zero | %F.S./10°C | 0.03 | Cable Ultimate Tension | N | 98 |
| Response Frequency | Hz | 1k | TEDS | Optional |