Features:
Compact structure, good stability, high precision, low mounting platform, safe and easy operation.
Application fields:
Compact structure, good stability, high precision, low mounting platform, safe and easy operation.Application fields: Platform scales, axle load scales, vehicle inspection lines, truck scales, hopper scales, tank scales, etc.
Measurements:

Capacity:
| Capacity (t) | A | B | C | D | E | ΦF |
|---|---|---|---|---|---|---|
| 0-3 | 114.3 | 177.8 | 104.8 | 152.4 | 88.9 | 11 |
| 5 | 152.4 | 235 | 136.5 | 184.2 | 101.6 | 17.5 |
| 10 | 203.2 | 355.6 | 190.5 | 304.8 | 152.4 | 20.6 |
| 20 | 228.6 | 406.4 | 228.6 | 342.9 | 165.1 | 28.5 |
| Capacity (t) | G | H | J | K |
|---|---|---|---|---|
| 0-3 | 12.7 | 25.4 | 19 | 50.8 |
| 5 | 25.4 | 31.8 | 25.4 | 65.1 |
| 10 | 25.4 | 44.5 | 44.5 | 96.8 |
| 20 | 31.8 | 50.8 | 50.8 | 114 |
Refer to Wiring Diagram:

Parameter:
| Parameter | Specification | Parameter | Specification |
|---|---|---|---|
| Capacity | 0-20T | Material | Stainless Steel / Alloy Steel |
| Rated Output | 2.0±0.05mV/V | Impedance | 350Ω |
| Zero Balance | ±1%F.S. | Insulation Resistance | ≥5000MΩ/100VDC |
| Non-Linearity | 0.03%F.S. | Operating Voltage | 5-15V |
| Hysteresis | 0.03%F.S. | Operating Temp Range | -20-80°C |
| Repeatability | 0.02%F.S. | Safe Overload | 150% |
| Creep (30min) | 0.03%F.S. | Maximum Overload | 200% |
| Temp Effect on Output | 0.03%F.S./10°C | Cable Specifications | φ5x3m |
| Temp Effect on Zero | 0.05%F.S./10°C | Cable Ultimate Pull | 10kg |
| Response Frequency | 10kHz | TEDS | Optional |